Highly Sensitive AP99-100, АР99-500, AP99-1000

    Destination:  

  • The measure seismic and mechanical vibrations of large engineering constructions and buildings (bridges, buildings, dams, etc.) in diagnostic systems and during laboratory studies.
    Features: 

  • Built-in preamplifier.
Parameter Unit АР99-100 АР99-500 АР99-1000
Axial sensitivity (± 10 %) mV/g*1 100 500 1000
Relative transverse sensitivity % < 5
Amplitude range g*1 ± 50 ± 10 ± 5
Max.shock limit (peak value) g*1 ± 2500 ± 500 ± 250
Operating temperature range °C -40…+ 125
Frequency range (ripple ± 1 dB) Hz 0.5…10 000
Self-resonant frequency in attached condition kHz > 15
Noise level, RMS (1 Hz … 10 kHz) g*1 < 0.0000 3 < 0.000 1
Output resistance Ohm < 500
Voltage power V + (15…30) + (18…30)
Current power mA 2…20
Constant output voltage level V 8…10 10…13
Turn-on time s 4
Housing material - stainless steel
(titanium alloy)*2
Weight (without connector and cable) gram 35
Supplied accessories - cable AK15,

stud АН0105

Options - T*3, N*4

 

 

General view of AP99

The typical electriacal circuit

The circuit of connection to a data-acquisition equipment

 


*1 – 1g = 9.807 m·s-2 or 10 m·s-2 = 1.02 g.;
*2 – to be determined when making out an order;
*3 – technology of interrogation TEDS (Transduser Electronic Data Sheet) is electronic tables of the given Vibration Transducers, it allows to define automatically the type of the Transducer and its characteristics, in conformity with the standard;
*4 – the normalized sensitivity (a deviation from face value is no more than 2 %).