D200

Purpose:

  • Measuring vibration displacement of machine and mechanism parts in stationary diagnostic systems.

Features:
  • Analog voltage output.
  • Transmission of output signal at a distance of up to 100 m.
  • Procedure for assessing technical condition of major equipment at service stations 70238424.27.140.001-2011 (for hydroelectric power plants).
  • MEMS technology.
  • Parameter
    Units of Measure
    D200
  • Vibration displacement measuring range
    µm
    ± 500
  • Frequency range at –1 dB
    Hz
    0,8 … 200
  • Conversion factor
    mV/µm
    10 ± 0,5
  • Operating temperature range
    °С
    – 20 … + 85
  • Coefficient of temperature variation influence on conversion factor
    %/°С
    ± 0,15
  • Cross sensitivity
    %
    <5
  • Amplitude nonlinearity
    %
    1.5
  • Maximum shock limit
    g
    ± 500*1
  • Noise level
    mV
    50
  • Power supply voltage
    V
    +(9...15)
  • Current consumption
    mA
    <15
  • Output resistance
    Ω
    <500
  • Maximum output voltage
    V
    ±5
  • Housing material
    -
    aluminium
  • Weight
    g
    150
  • Connector type
    -
    2РМГ14БП4Ш1В1
  • Overall dimensions
    mm
    71 × 50 × 35
  • Supplied accessories
    -
    cable AK51P6A4, stud АН0105, magnet mounting base АМ08
External view of D200
Электрическая схема D200
Схема подключения

Optional accessories:

  • calibrators АТ01, АТ02;
  • cable АК33;
  • insulating stud AH1010.

 

*1 – 1 g = 9.807 m·s–2