AV02-03-0.08

Purpose:

  • Measuring vibration velocity in stationary diagnostic systems with standard current output (4–20 mA).

Features:
  • Conversion of a piezoelement signal proportional to vibration velocity into a standard current signal 4 … 20 mA.
  • HART-protocol (Highway Addressable Remote Transducer Protocol) – digital industrial protocol for transfer of data superimposed on a current analog loop of 4 … 20 mA.
  • Electric insulation of piezoelement and built-in amplifier-transducer from the body eliminates the influence of grounding loop currents on measurement results.
  • Robust design, waterproof casing and non-detachable armored cable.
  • Stable characteristics and reliable operation.
  • Transmission of current signal at a distance of up to 500 m.
  • Evaluation of machines vibration according to GOST ISO 10816-3-2002.
  • Explosion-proof version 1ExibIICT4 (optional).
  • Parameter
    Units of Measure
    AV02-03-0.08
  • Conversion factor for vibration velocity to current signal 4 … 20 mA
    mA∙s/mm
    0.08±0.004
  • Vibration velocity measuring range
    mm/s
    1...200
  • Vibration velocity frequency range
    Hz
    2...1000
  • Variation in frequency response relative to the basic frequency value 159. 15 Hz, within:
    %
    from 3 to -12.5
  • Relative coefficient of transverse conversion
    %
    < 5
  • Self-resonant frequency in the fastened state
    kHz
    > 25
  • Maximum vibration acceleration (peak value)
    m/s2
    100
  • Operating temperature range
    °С
    –40...+85
  • Ambient temperature influence coefficients, within:
    %/°С
    ± 0,2
  • Power from external source of voltage dc
    V
    + (9 ... 25)
  • Load resistance in the current output circuit:
    - at power supply voltage 9 V
    - at power supply voltage 25 V
    Ω
    ≤100; ≤850
  • Run mode setting time
    s
    <4
  • Housing material
    -
    нержавеющая сталь
  • Built-in cable length
    m*2
    2
  • Weight (without cable)
    g
    95
  • Cable protection
    -
    metal hose
  • Supplied accessories
    -
    screw М6-8g × 55
  • Explosion-proof version
    -
    1ExibIICT4 *2
External view of AV02-03-0.08
Electrical circuit of AV02-03-0.08

Optional accessories:

  • calibrators АТ01m, АТ02;
  • power unit AS03;
  • magnet mounting base АМ13-01;
  • stud AН1006.


*1HART – protocol (Highway Addressable Remote Transducer Protocol) – digital industrial protocol for transfer of data superimposed on a current
analog loop of 4 … 20 mA.

*2 – To be determined by customer.

Catalog

  • ru