AP2086-100

Purpose:

  • Measuring vibration and shock acceleration in diagnostic systems and laboratory tests under strong electromagnetic fields.

Features:
  • Built-in preamplifier.
  • Electrically insulated piezoelement and built-in preamplifier.
  • High axial sensitivity, self-resonant frequency and shock resistance.
  • Low sensitivity to electromagnetic fields.
  • Wide range of power supply voltage and current.
  • Low level of intrinsic noise.
  • Explosion-proof version 1ExibIICT4 (optional).
  • Captive screw.
  • Parameter
    Units of Measure
    AP2086-100
  • Conversion factor
    mV/(m·s–2)
    10
  • Relative coefficient of transverse conversion
    %
    <5
  • Maximum value of measured vibroacceleration amplitude
    m/s2
    500
  • Maximum shock limit (peak value)
    g*1
    ±500
  • Operating temperature range
    °С
    –40 ... +125
  • Coefficient of ambient temperature variation influence (from – 40 °С to + 125 °С) on axial sensitivity
    %/°С
    0.2
  • Operating frequency range (ripple ± 1 dB)
    Hz
    1 ... 6 000
  • Self-resonant frequency in the fastened state
    kHz
    >30
  • Noise level, RMS (1 Hz ÷ 10 kHz)
    m/s2
    0,003
  • Output resistance
    Ω
    <500
  • Power:
    - voltage
    - current

    V;
    mA

    +(18 ... 30);
    2 ... 20
  • Constant output voltage level, at Un = 15 V
    V
    8 ... 11
  • Housing material
    stainless steel
  • Built-in cable length
    m*2
    2
  • Connector type *2
    cable termination cable termination,
    cable protection bellows,
    IP68 - (01) AR0701 (5/8-24 UNF) - (02)
  • Weight (without cable)
    g
    80
  • Supplied accessories
    cable AK31C1A3 - (02)
  • Options
    T, N*3
External view of AP2086-100
Electrical circuit of

Optional accessories:

  • charge and voltage amplifiers AP5030, AP5210, AP5220, AP5230, AP52400B1, AP5240A1B1, AP5250;
  • measuring amplifiers AP5110, AP5200;
  • matching devices AG01-01, AG02-01;
  • calibrators AT01m, AT02, AT04;
  • cable adapters AR01, AR04;
  • power units AS03;
  • magnet mounting bases АМ03-02, AM13-01;
  • studs AH0806, AH1006.

*1 – 1 g = 9.807 m·s–2 or 10 m·s–2 = 1.02 g;
*2 – to be determined by customer;
*3 – TEDS poll technology (Transducer Electronic Data Sheet) – electronic work sheets that automatically define the type of sensor
and its technical characteristics according to IEEE P1451.4.
Normilized sensitivity (nominal deviation not more than 2 %).

Catalog

  • ru
  • +7 (831-30) 6-77-77