AP2006-500-01

Purpose:

  • Measuring seismic and mechanical vibrations (from 0.1 Hz) of large engineering constructions (bridges, buildings, dams, etc.) in portable
    diagnostic systems and stationary monitoring facilities.

Features:
  • Shear structure of piezoelement operation.
  • Robust design and waterproof casing.
  • Stable characteristics and reliable operation.
  • Wide range of power supply voltage and current.
  • Low level of intrinsic noise.
  • Parameter
    Units of Measure
    AP2006-500-01
  • Conversion factor
    mV/m·s-2
    50
  • Relative coefficient of transverse conversion
    %
    <5
  • Maximum value of measured vibroacceleration amplitude
    m/s2
    100
  • Maximum shock limit (peak value)
    g *1
    ±100
  • Operating temperature range
    °С
    – 55 … + 125
  • Temperature variation sensitivity cutoff frequency HFF
    0.2 Hz
    3 Hz
    g/°С

    0.002;
    0.0005
  • Operating frequency range (ripple ± 1 dB)
    Hz
    0.1...2 000
  • Adjustment resonance frequency in axial direction
    kHz
    >7
  • Noise level, RMS (0.1 … 2 000 Hz)
    m/s2
    <0.0001
  • Output resistance
    Ω
    <500
  • Power:
    - voltage;
    - current

    В;
    мА

    +(18...30);
    2...20
  • Constant output voltage level
    V
    8...13
  • Temperature influence coefficient
    %/°С
    ±0.2
  • Run mode setting time
    s
    10
  • Housing material
    -
    stainless steel
  • Weight (without cable)
    g
    180
  • Connector type
    -
    cable termination/ BNC
  • Cable protection
    -
    metal hose
  • Supplied accessories
    -
    stud АН0110
External view of AP2006-500-01
Electrical circuit of AP2006-500-01

Optional accessories:

  • calibrators AT01m, AT02;
  • cable AK26;
  • matching device AG05-01;
  • power unit AS06;
  • magnet mounting bases AM03;
  • wax mastic AW01.

*1 – 1 g = 9.807 m·s–2 or 10 m·s–2 = 1.02 g

Catalog

  • ru
  • +7 (831-30) 6-77-77