AP1006

Purpose:

  • Measuring seismic and mechanical vibrations (from 0.01 Hz) of large engineering structures and constructions (bridges,
    buildings, dams, etc.) in portable diagnostic systems and stationary monitoring facilities.

Features:
  • Shear-based operation of piezoelement.
  • Electric insulation between sensing element and casing.
  • Robust design and waterproof casing.
  • Stable characteristics and reliable operation.
  • Parameter
    Units of Measure
    AP1006
  • Conversion factor
    pC/m·s-2
    100
  • Relative coefficient of transverse conversion
    %
    <5
  • Maximum value of measured acceleration amplitude
    m/s2
    100
  • Maximum shock limit (peak value)
    g*1
    ±100
  • Operating temperature range
    °С
    –80 ... +120
  • Operating frequency range (ripple ± 1 dB)
    Hz
    0.01 ... 2 000
  • Self-resonant frequency in secured condition
    kHz
    >7
  • Strain sensitivity
    gmּ/μm
    <0.0005
  • Electric capacity
    pF
    3 000 (±500)
  • Insulation resistance in normal conditions
    GOhm
    100
  • Temperature variation sensitivity
    %/°С
    0.2
  • Sensitivity to variable temperature HF filter cutoff frequency 0.2 Hz; 3 Hz
    g/°С
    0.002; 0.0005
  • Housing material
    stainless steel
  • Weight (without cable)
    g
    165
  • Connector type
    AR09
  • Cable protection
  • Supplied accessories
    stud AH0105, cable AK20
External view of AP1006
Electric circuit of AP1006

Optional accessories:

  • charge amplifiers AQ05-Д.Х.ХХХ;
  • matching device AG05;
  • calibrators AT01m, AT02;
  • charge and voltage amplifier АР5240А3;
  • magnet mounting base АМ03;
  • wax mastic AW01.

*1 – 1g = 9.807 m·s-2 or 10 m·s-2 = 1.02 g.